Developed exclusively for the streamlined treatment of brain tumors, lesions, and other conditions of the head and neck, ZAP-X® Gyroscopic Radiosurgery® platform redefines the future of radiosurgery and aspires to set new standards in SRS delivery.

Minimizing 3D Dose Gradient

To simultaneously optimize dose fall-off and conformality, ZAP-X’s dual independent gantries allow for an unparalleled spherical workspace and simple delivery of >1000 unique non- coplanar beam angles – not as an exception, but as routine clinical practice.

Reducing Radiation Leakage

Utilizing a tungsten-shielded circular collimation system, ZAP-X lowers radiation leakage to less than 0.002% of the primary beam. Compared to the 3.00% maximum potential leakage of multi- purpose platforms, ZAP-X aims to strictly limit healthy brain exposure and lower the risk of inducing patient neurocognitive deficit.

Decreasing Radiation Scatter

ZAP-X is exclusively designed to significantly reduce non-therapeutic dose to adjacent critical structures. Unlike the high-scatter 6-10 MV beam energies commonplace with multi-purpose radiation delivery platforms, ZAP-X is tailor-made for SRS with a 3 MV beam (approximate equivalent to the 1.25 MeV beam of Co-60).

Sharpening Beam Penumbra

The SRS-only design of ZAP-X allows for an unprecedented linac source-axis distance (SAD) of 45 cm – reducing beam penumbra by ~50% from the 100 cm SAD typical of full-body radiation platforms. The potential benefit: less dose to the eyes, optic nerves, brain stem, and other organs at-risk.

REDUCING BARRIERS BY LOWERING TOTAL COST OF OWNERSHIP

Removing the financial constraints that have historically concentrated world-class radiosurgery primarily among the well-funded urban academic hospital, the novel innovations of ZAP-X expand SRS access and introduce new benchmarks in cost-efficient, high-quality care.

NO VAULT

As the first and only vault-free SRS delivery system, ZAP-X eliminates the requirement of 2- 3M pounds of high-density concrete and steel for shielded radiation bunker construction, and ~$1M+ USD in infrastructure expense.

NO COBALT

Utilizing a modern 1500MU/min linear accelerator, ZAP-X eliminates the recurring ~$1M USD cost for live radioactive source replacements and removes the related overhead expense for arduous regulatory licensing and source security.